FTS 812(L) LED REIL and RTIL Lights

Approach Lighting

FTS 812(L) LED REIL and RTIL Lights
FTS 812(L) LED REIL and RTIL LightsFTS 812(L) LED REIL and RTIL LightsFTS 812(L) LED REIL and RTIL LightsFTS 812(L) LED REIL and RTIL Lights

FTS 812(L) LED REIL and RTIL Lights

A runway threshold identification light (RTIL) or runway end identifier light (REIL) system consists of two synchronized, unidirectional flashing lights visible from three miles during the day and 20 miles at night or poor weather conditions. Installed facing the approach, REIL/RTIL lights mark the end of an active runway. The FTS 812(L) is an LED voltage-driven RTIL that complies with FAA L-849 Styles A and E. Used as a simple REIL, the FTS 812(L) offers three intensity settings. The flashhead and power converter may be mounted together or separately to adapt to specific terrain needs.

  • Modular design for easy maintenance
  • Long-lasting LED flashheads require a low operational voltage
  • Configure for 1- or 3-step intensity
  • Compatible with air-to-ground radio controllers and ground-to-ground remote systems
  • Optional remote-mounted power controller

FLASHHEAD – FH 800

Flash Rate

  • 60 or 120 fpm

Coverage

  • 30° minimum horizontal coverage

Beam

  • 10° vertical beam

Elevation Angle

  • Adjustable elevation angle 0 to 15°

VOLTAGE-DRIVEN POWER CONVERTER – PC 800(L)

Power *

  • Single FH with Controller
    High: 35.5 W, Medium: 10 W, Low 8 W
  • Two FH with Controller
    High: 64.5 W, Medium: 16 W, Low 12 W

Voltage

  • 120-240 VAC, 50 and 60 Hz

Amperage *

  • 171 VA at 120 VAC
  • 193 VA at 99 VAC

Interlocks

  • Yes

Internal Surge Protection

  • Yes

Construction

  • Powder-coated aluminum beacon and power converter, stainless steel hardware

Temperature

  • -40 to +131°F (-40 to +55°C)

Protection Rating

  • IP 65, NEMA 4

WEIGHT AND DIMS

FTS 812(L) Co-mounted Assembly

  • Width: 18.6 in (473 mm)
  • Height: 19 in min-32.5 in max (483 mm min-826 mm max)
  • Depth: 21.5 in (546 mm)
  • 37.9 lbs (17.2 kg) **

FTS 812(L) Remote Mount Assembly

  • Width: 7.9 in (201 mm)
  • Height: 19 in min-32.5 in max (483 mm min-826 mm max)
  • Depth: 16.5 in (419 mm)
  • 18.8 lbs (8.5 kg) **

PC 800(L) Power Converter ***

  • Width: 12.8 in (325 mm)
  • Height: 18.6 in (473 mm)
  • Depth: 7.7 in (196 mm)
  • 17.1 in (7.8 kg)

* Power and amperage reflects two flashheads.
** Does not include 2” EMT conduit or any fittings below it.
*** Does not include flashhead mounting brackets.

CONFIGURATION

Mounting

  • Permanent
  • Portable

Output

  • Visible
  • Visible/IR

Power

  • Solar
  • Generator
  • Battery
  • AC

Control

  • Wired

LIGHTING INTENSITIES

Style High Intensity Medium Intensity Low Intensity
A 15,000 ecd
E 15,000 1,500 300
Description

A runway threshold identification light (RTIL) or runway end identifier light (REIL) system consists of two synchronized, unidirectional flashing lights visible from three miles during the day and 20 miles at night or poor weather conditions. Installed facing the approach, REIL/RTIL lights mark the end of an active runway. The FTS 812(L) is an LED voltage-driven RTIL that complies with FAA L-849 Styles A and E. Used as a simple REIL, the FTS 812(L) offers three intensity settings. The flashhead and power converter may be mounted together or separately to adapt to specific terrain needs.

  • Modular design for easy maintenance
  • Long-lasting LED flashheads require a low operational voltage
  • Configure for 1- or 3-step intensity
  • Compatible with air-to-ground radio controllers and ground-to-ground remote systems
  • Optional remote-mounted power controller
Features

FLASHHEAD – FH 800

Flash Rate

  • 60 or 120 fpm

Coverage

  • 30° minimum horizontal coverage

Beam

  • 10° vertical beam

Elevation Angle

  • Adjustable elevation angle 0 to 15°

VOLTAGE-DRIVEN POWER CONVERTER – PC 800(L)

Power *

  • Single FH with Controller
    High: 35.5 W, Medium: 10 W, Low 8 W
  • Two FH with Controller
    High: 64.5 W, Medium: 16 W, Low 12 W

Voltage

  • 120-240 VAC, 50 and 60 Hz

Amperage *

  • 171 VA at 120 VAC
  • 193 VA at 99 VAC

Interlocks

  • Yes

Internal Surge Protection

  • Yes

Construction

  • Powder-coated aluminum beacon and power converter, stainless steel hardware

Temperature

  • -40 to +131°F (-40 to +55°C)

Protection Rating

  • IP 65, NEMA 4

WEIGHT AND DIMS

FTS 812(L) Co-mounted Assembly

  • Width: 18.6 in (473 mm)
  • Height: 19 in min-32.5 in max (483 mm min-826 mm max)
  • Depth: 21.5 in (546 mm)
  • 37.9 lbs (17.2 kg) **

FTS 812(L) Remote Mount Assembly

  • Width: 7.9 in (201 mm)
  • Height: 19 in min-32.5 in max (483 mm min-826 mm max)
  • Depth: 16.5 in (419 mm)
  • 18.8 lbs (8.5 kg) **

PC 800(L) Power Converter ***

  • Width: 12.8 in (325 mm)
  • Height: 18.6 in (473 mm)
  • Depth: 7.7 in (196 mm)
  • 17.1 in (7.8 kg)

* Power and amperage reflects two flashheads.
** Does not include 2” EMT conduit or any fittings below it.
*** Does not include flashhead mounting brackets.

CONFIGURATION

Mounting

  • Permanent
  • Portable

Output

  • Visible
  • Visible/IR

Power

  • Solar
  • Generator
  • Battery
  • AC

Control

  • Wired

LIGHTING INTENSITIES

Style High Intensity Medium Intensity Low Intensity
A 15,000 ecd
E 15,000 1,500 300
Compliance
Downloads
FacebookTwitterGoogle PlusLinkedinEmail